Thermocouple Data Logger with USB Interface & LCD Display










The ATP Thermocouple Data Logger with USB Interface and LCD Display (GP model) offers a convenient and accurate way to monitor and record temperature over time. Compatible with K, J, and T-type thermocouples, it provides flexibility for various applications and environments, with a wide temperature range from -200°C to +1350°C (dependent on probe type).
This logger features a clear LCD display for real-time temperature readings and status alerts. With a generous memory capacity of 32,000 readings and adjustable logging intervals, it is well suited for short-term studies or long-term monitoring projects. Data can be easily downloaded via USB using the supplied software, allowing for detailed analysis and reporting. The unit is supplied with a K-Type probe and a traceable calibration certificate, ensuring confidence and compliance in critical applications.
-
Supports K, J, and T-type thermocouples for wide compatibility
-
Logs up to 32,000 temperature readings
-
USB interface for easy data download and analysis
-
Real-time LCD display for instant feedback
-
Adjustable logging intervals (2 sec to 24 hrs)
-
Supplied with bead probe, software, and wall bracket
-
Includes traceable calibration certificate for assurance
-
Range: -200° to +1350°C (K-Type), -200° to +1190°C (J-Type),
-200° to +390°C (T-Type)Resolution: 0.5°C Accuracy: ±1°C (-10° to +40°C) ±2°C others Logging Rate: From 1 sec up to 12 hrs (user selectable) Max Readings: 32,510 data sets Dimensions: 118 x 27 x 26mm Power: 1 x 3.6V ½AA lithium battery (SB-AA02) typical 6 months Weight: 39g
-
A calibration service can be purchased for this unit. Once the Service has been performed a certificate of calibration is produced and dispatched with your order. Calibration Services are performed on receipt of your order and as such will delay shipping. Details and options are outlined below.
Traceable Calibration (K-Type Unit Only) Issued at 9 points: -20°C, 20°C, 50°C, 100°C, 200°C,
300°C, 400°C, 500°C, & 1000°CAdditional points: From -160 to 1260°C Traceable Calibration (K-Type System - Unit + 1 Probe) Issued at 4 points: 25, 50, 100, & 140°C Additional points: From -20 to 140°C UKAS Calibration (K-Type System - Unit + 1 Probe) Issued at 4 points: 25, 50, 100, & 140°C Additional points: -20 to 255°C A UKAS calibration can also be considered traceable. The difference between the two is that UKAS calibrations are carried out under the remit of an ISO/IEC 17025 quality system by a laboratory that has been accredited by UKAS, to ensure the consistency and accuracy of results.
-
View our selection of thermocouple probes. From penetration to surface probes we have a selection available in K, J, E, T, R, S
Write Your Own Review -