Airflow Calibration

Airflow Calibration Services

Airflow CalibrationOur in-house calibration laboratory offers traceable calibration services on the majority of Vane and Hot Wire Anemometers. The turnaround time can be as quick as 2-3 working days and calibration also includes free adjustment of your equipment, back into the manufacturer's specification, where possible.

Airflow calibration typically ranges from 6 m/sec to 18 m/sec. Should these points not meet your application, additional points can be purchased between 0.5 m/sec to 20 m/sec or customised to meet your full requirements. Where applicable we can also test the Temperature element of your Anemometer for full linearity. This is an optional add on service.

To contact our calibration team, call: 01530 566804

Airflow Calibration Options

Instrument Type: Airflow
Calibration Points: 6, 12 & 18 m/sec
Temperature: 20°C & 30°C
* Traceable certification is adequate for most applications and meets the calibration requirements of ISO 9001. All measurements contained in this type of certification are traceable back to National UKAS Standards..

Air Flow Calibration Procedure

Step 1: Send us your instruments

Instrumentation can be sent to us with a copy of your official order, or order confirmation. Alternatively, we can arrange a collection via our own designated courier (charges apply). Please contact our Technical Team who will be happy to arrange this. Please ensure your instruments are clean and free from contaminants.

Step 2: Booking in

When you instrument arrives on-site it undergoes an initial inspection by our calibration staff. The instrument is checked for any damage, and functionality and the batteries are tested for the correct voltage. If required, new batteries are installed and the item is booked in and placed safely inside our lab to acclimatise to the testing environment for 24 hours. Should any faults or damage be found our team will contact you to discuss your options.

Step 3: Testing

Your Anemometer is calibrated using a specialist Halogen or LRD lightbox, where its accuracy is recorded and compared against UKAS calibrated equipment at pre-determined calibration points. If your meter is reading out of specification, our technicians will adjust it where possible and re-test.

Step 4: Producing your Airflow Calibration Certificate

Your test data is detailed on calibration certificates which include testing conditions, equipment used, measurement errors, and any measurements of uncertainty ensuring full traceability.

Step 5: Payment and Shipping

Our calibration team will contact you with an update about your instruments and request payment. Your items are then safely repackaged and shipped via express delivery that typically arrives the very next day.

Why Choose ATP for your Calibration?

With over 30 years of experience, we have tailored our calibration services to offer the very best in convenience.

Customisable Calibration

All our calibrations come with standard issued points. Should these not fulfill the needs of your application we offer purchasable additional points or even the option for you to fully customise your calibration to points of your choosing.

Fast Calibration

We know that being without your instrumentation can cause disruption to your business. As such our light calibration services come with a typical 2-4 day turnaround on receipt of the item, subject to no faults being found.

Battery Checks / Replacement

All instrument batteries should be checked and replaced if low voltage prior to calibration. We do this for you and replace all batteries if required for a minimal charge.

Instrument Adjustment / Repair

If your instrument is found to be out of spec or faulty we will do our best to adjust and repair your instrument as part of the calibration.

Replacement Instrumentation

Should an unfixable fault be found in your instrument, our online store is ready with replacement instruments in stock and ready to ship to cause minimal disruption to your business.